1.
World Neurosurg ; 152: e235-e240, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34058357

RESUMO

BACKGROUND: One of the most preventable errors of a surgeon's career is operating on the incorrect surgical site (ICSS). No study in any specialty has ever investigated the incidence of ICSS events in lower-income countries. This study focuses on identifying the occurrence of these events along with an analysis of potential causes leading to these unfortunate events. METHODS: The authors distributed a survey to neurosurgical colleagues from around the world. These surgeons were first asked to identify details about their practice and incidence and personal experience with ICSS in their own careers. At the end of the survey, they responded to questions about their knowledge of safety checklists. RESULTS: In this study there was a 63.4% response rate. When combined with those who participated through various social media platforms, there were 178 responses. The incidence rate for every 10,000 cases performed was found to be 22.8 in the cranial group, 88.6 in the cervical group, and 158.8 in the lumbar procedural group. This study identified that 40% of participants had never learned or experienced the ABCD time-out strategy and that 60% of surgeons did not use intraoperative navigation or imaging in their practices. The error has never been disclosed to the patient in 48% of the ICSS cases. CONCLUSIONS: Due to a lack of application of safety checklist protocol, there is an increased occurrence of ICSS events in lower-income countries. The results of this study demonstrate the necessity of investing time and resources dedicated to avoiding preventable errors.


Assuntos
Países em Desenvolvimento/estatística & dados numéricos , Erros Médicos/estatística & dados numéricos , Procedimentos Neurocirúrgicos/estatística & dados numéricos , Encéfalo/cirurgia , Vértebras Cervicais/cirurgia , Lista de Checagem , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Incidência , Vértebras Lombares/cirurgia , Erros Médicos/prevenção & controle , Neuronavegação , Neurocirurgiões , Cirurgia Assistida por Computador , Inquéritos e Questionários
2.
Talanta ; 43(2): 247-53, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18966485

RESUMO

A solid ion-pair material produced from ammonium tetraphenylborate on naphthalene (ATPB-naphthalene) provides a simple, rapid, economical and selective technique for preconcentrating iron from approximately 500 ml of aqueous solution of standard alloys and biological samples. Iron reacts with 2-(5-bromo-2-pryidlazo)-5-diethylaminophenol (5-Br-PADAP) to form a water-soluble cationic complex. When the aqueous solution of this cationic species in the pH range 3.2-8.5 is passed over the adsorbent ATPB-naphthalene at a flow rate of 1 ml min(-1), it is quantitatively retained on naphthalene as an uncharged ion-associated complex. The solid mass from the column was dissolved out with 5 ml of dimethylformamide (DMF) and iron is determined by third derivative spectrophotometry by measuring the signal d(3)A/ dlambda(3) between lambda(2)(773 nm) and lambda(3)(737 nm). The calibration curve is linear over the concentration range 0.10-25.0 mug of iron in 5 ml of DMF solution. Eight replicate determinations of 5 mug of iron gave a mean intensity (peak-to-peak signal between lambda(2) and lambda(3)) of 1.534 with a relative standard deviation of 0.90%. The sensitivity of the method is 0.307 (d(3)A/dnm(3) )/mug found from the slope of the calibration curve. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of iron in various standard alloys and biological samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA